Öffnung der Vene und Vorschieben eines 8 Fr. Portkatheters, der unter Bildwandlerkontrolle in der Vena cava superior plaziert wird.
Proposed translations
(English)
Change log
Jan 15, 2015 16:39: Steffen Walter changed "Field (specific)" from "(none)" to "Medical: Instruments"
Proposed translations
+3
26 mins
Selected
monitored by an image converter
Bildwandler = image converter (optics)
Kucera
Kucera
4 KudoZ points awarded for this answer.
Comment: "Thank you all for your suggestions."
25 mins
under x-ray control
"Bildwandler" is a mobile x-ray unit used in theatres or cardio labs.
--------------------------------------------------
Note added at 2003-06-16 12:34:55 (GMT)
--------------------------------------------------
see following address for pictures: www.medical.philips.com/main/products/cardiovascular/produc...
--------------------------------------------------
Note added at 2003-06-17 06:19:35 (GMT)
--------------------------------------------------
... In enger Kooperation mit der Kardiologie der Medizinischen Klinik (Prof.
Dr. Scriba, Prof. ... 153. Röntgen-Untersuchungen mit Bildwandler. 208. ...
link.medinn.med.uni-muenchen.de/ inn/lb.1996/lb.1.2.html
--------------------------------------------------
Note added at 2003-06-17 06:34:14 (GMT)
--------------------------------------------------
Der Katheter wird bei Einbringen von rechts ca. 16 cm weit, links ca. 20 cm weit vorgeschoben und die Lage anschließend unter Bildwandler kontrolliert. Da die meisten Katheter röntgendicht sind ist eine Applikation von Kontrastmittel nur selten erforderlich. Die Katheterspitze sollte vor dem rechten Vorhof in der oberen Hohlvene liegen.
http://www.bdem.de/tagungen/abstracts2/portimplantation.htm
--------------------------------------------------
Note added at 2003-06-16 12:34:55 (GMT)
--------------------------------------------------
see following address for pictures: www.medical.philips.com/main/products/cardiovascular/produc...
--------------------------------------------------
Note added at 2003-06-17 06:19:35 (GMT)
--------------------------------------------------
... In enger Kooperation mit der Kardiologie der Medizinischen Klinik (Prof.
Dr. Scriba, Prof. ... 153. Röntgen-Untersuchungen mit Bildwandler. 208. ...
link.medinn.med.uni-muenchen.de/ inn/lb.1996/lb.1.2.html
--------------------------------------------------
Note added at 2003-06-17 06:34:14 (GMT)
--------------------------------------------------
Der Katheter wird bei Einbringen von rechts ca. 16 cm weit, links ca. 20 cm weit vorgeschoben und die Lage anschließend unter Bildwandler kontrolliert. Da die meisten Katheter röntgendicht sind ist eine Applikation von Kontrastmittel nur selten erforderlich. Die Katheterspitze sollte vor dem rechten Vorhof in der oberen Hohlvene liegen.
http://www.bdem.de/tagungen/abstracts2/portimplantation.htm
Peer comment(s):
neutral |
Michele Johnson
: I think this could be more general imaging, not just x-ray; see LaRoch dict, http://www.gesundheit.de/roche/ro02500/r3786.html
15 mins
|
26 mins
(vein) viewer controlled
Bildwandler is (CMOS) viewer
It may be an appliance like:
http://www.afrlhorizons.com/Briefs/Dec01/ML0106.html
It may be an appliance like:
http://www.afrlhorizons.com/Briefs/Dec01/ML0106.html
+1
26 mins
image-guidance
A general term which refers to the use of imaging techniques to guide robotic instruments in 'minimally invasive' surgery
Reference:
http://www.irus.rri.on.ca/igns/achiu.html
http://www.academicradiology.com/AR_2001/Sep01/5c090100819p.PDF
51 mins
image intensification
As mentioned from the Roche dictionary. Maybe something like "with the help of image intensification" might work for you. Everything I try with "image intensifier" sounds odd (image-intensifier guided?)
http://www.gesundheit.de/roche/ro02500/r3786.html
http://www.aaos.org/wordhtml/anmeet99/sciprog/p.htm
1. Using bi-plane image intensification...
... C-arm image intensifier is used to visualize the fracture.
http://www.gesundheit.de/roche/ro02500/r3786.html
http://www.aaos.org/wordhtml/anmeet99/sciprog/p.htm
1. Using bi-plane image intensification...
... C-arm image intensifier is used to visualize the fracture.
+3
6 hrs
monitored by fluoroscopy
A Bildwandler is called an image converter in optics, but when this is used in medicine to position catheters and the like, it is called fluoroscopy and the machine is called a fluoroscope. This is the correct medical terminology - not "image converter".
--------------------------------------------------
Note added at 2003-06-24 13:24:00 (GMT) Post-grading
--------------------------------------------------
I guarantee you that in medicine this is fluoroscopy - NOT an image converter!!!
--------------------------------------------------
Note added at 2003-06-24 13:24:00 (GMT) Post-grading
--------------------------------------------------
I guarantee you that in medicine this is fluoroscopy - NOT an image converter!!!
Peer comment(s):
agree |
Elisabeth Ghysels
: or simply "under fluoroscopy" indeed, f.i. http://www.medscape.com/viewarticle/410644_3
41 mins
|
agree |
heikeb
: "under fluoroscopy". Definitely fluoroscopy!
1243 days
|
agree |
Lirka
3940 days
|
Something went wrong...